AW 5524B-2

Select Operating Condition
Application
LBP
MBP
LBP/MBP
MBP/HBP
HBP
HBP/AC
AC
CBP
Operating Condition
Calculate the Capacity & Efficiency of Compressor at different operating conditions
ARI
ASHRAE
CECOMAF
EN12900
Evaporation Temp. [°F]
Condensing Temp. [°F]
Return Temp. [°F]
Liquid Temp. [°F]
Superheating [K]
Subcooling [K]

AW 5524B-2

Type: Application: AC
Refrigerant: R410A Voltage [V] / Frequency [Hz] / Phases: 208-230 V. 60 Hz.
Motor type: P.S.C. Cooling capacity: 7,414
Starting torque: Efficiency: 10.6
HP:1-3/5 Displacement [cm³]:32.7
Data

    Nominal Performance

    Cooling Capacity 7,414
    Power Input 2,480
    Locked Rotor Amps 55
    Rated Load Amps 11
    COP (EER) 10.2

    Testing Condition

    Condensing Temperature 54.4
    Evaporating Temperature 7.2
    Liquid Temperature 46.1
    Return Gas Temperature 35
    Ambient Temperature 35

    Application

    Evaporating Range 0.00°C to 13.00°C
    Refrigerant R410A
    Expansion No
    Compressor Cooling No

    Electrical Components

    Motor Protector Type No
    Model Number 4042KGE656-10
    Open / Close 130-140 / 60-78 ° C
    1st Cycle Trip at 25 ° C
    Motor Starter Type No
    Model Number 4043KGE681-9 (RVA4AM6D)
    Pick Up (max.) 242.00-272.00 Volts
    Drop Out ( min. ) 60.00-121.00 Volts
    Terminal Cover KGM 901-3
    Start Capacitor 161-193 µF 330 VAC.
    Disch Resistor for Start Cap
    Run Capacitor 50 µF 440 VAC

    Mounting Kit

    Rubber Grommet 4007KGM905-2
    Sleeve Grommet 4023KGM903-2
    Washer
Performance

    Performances at standard check-points

    Checkpoint Cooling capacity +/-5% Power consumption +/-5% Gas flow rate +/-5% Cooling Efficiency +/- 7% Heating capacity +/- 5% * Heating Efficiency +/- 7%
    W W kg/h W/W W W/W
    ARI HBP 379.43 162.62 10.16 2.33 464.15 2.85
    ARI MBP 225.21 125.86 6.04 1.79 289.20 2.30
    ASHRAE CBP 243.00 131.21 5.29 1.85 312.48 2.38
    ASHRAE HBP 32 482.63 163.08 9.61 2.96 568.53 3.49
    ASHRAE HBP 46 429.60 163.14 9.51 2.63 515.68 3.16
    * Calculations performed considering isentropic compression and a housing loss of 10%. This is an estimated heat amount discarded in the discharge pipe and the condenser combined.
    Tables

    Condensing Temp. 35°C (Subcooling : 0 K, Return Temp.: 32 °C)

    Evaporating temperature Cooling capacity +/-5% Power consumption +/-5% Gas flow rate +/-5% Cooling Efficiency +/- 7% Heating capacity +/- 5% * Heating Efficiency +/- 7%
    °C W W kg/h W/W W W/W
    -15.00 198.48 99.10 3.96 2.00 245.93 2.48
    -10.00 247.83 106.91 4.96 2.32 299.29 2.80
    -5.00 307.85 114.36 6.19 2.69 362.71 3.17
    Charts

    Cooling capacity [W]

    Condensing temperature [°C]

    35

    45

    55

    Power consumption [W]

    Condensing temperature [°C]

    35

    45

    55

    Gas flow rate [kg/h]

    Condensing temperature [°C]

    35

    45

    55
Drawings
    No drwaings available for this product