LA 5610EXT

Select Operating Condition
Application
LBP
MBP
LBP/MBP
MBP/HBP
HBP
HBP/AC
AC
CBP
Operating Condition
Calculate the Capacity & Efficiency of Compressor at different operating conditions
ARI
ASHRAE
CECOMAF
EN12900
Evaporation Temp. [°F]
Condensing Temp. [°F]
Return Temp. [°F]
Liquid Temp. [°F]
Superheating [K]
Subcooling [K]

LA 5610EXT

Type: Application: AC
Refrigerant: R22 Voltage [V] / Frequency [Hz] / Phases: 200-230 V. 60 Hz. ; 3 Phase
Motor type: 3 Phase. Cooling capacity: 87,000/105,000
Starting torque: Efficiency: 9.9
HP:8-3/4 Displacement [cm³]:197
Data

    Nominal Performance

    Cooling Capacity 87,000/105,000
    Power Input 8790/10600
    Locked Rotor Amps 208
    Rated Load Amps 27
    COP (EER) 9.9 / 9.9

    Testing Condition

    Condensing Temperature 54.4
    Evaporating Temperature -7.2
    Liquid Temperature 46.1
    Return Gas Temperature 35
    Ambient Temperature 35

    Application

    Evaporating Range 0.00 ° C to 13.0
    Refrigerant R22
    Expansion No
    Compressor Cooling No

    Electrical Components

    Motor Protector Type No
    Model Number KLE 656-2
    Open / Close
    1st Cycle Trip at 25 ° C
    Motor Starter Type No
    Model Number
    Pick Up (max.)
    Drop Out ( min. )
    Terminal Cover KLD 901
    Start Capacitor No μF No VAC.
    Disch Resistor for Start Cap
    Run Capacitor No μF No VAC.

    Mounting Kit

    Rubber Grommet KLD 905
    Sleeve Grommet KLD 903
    Washer
Performance

    Performances at standard check-points

    Checkpoint Cooling capacity +/-5% Power consumption +/-5% Gas flow rate +/-5% Cooling Efficiency +/- 7% Heating capacity +/- 5% * Heating Efficiency +/- 7%
    W W kg/h W/W W W/W
    ARI HBP 379.43 162.62 10.16 2.33 464.15 2.85
    ARI MBP 225.21 125.86 6.04 1.79 289.20 2.30
    ASHRAE CBP 243.00 131.21 5.29 1.85 312.48 2.38
    ASHRAE HBP 32 482.63 163.08 9.61 2.96 568.53 3.49
    ASHRAE HBP 46 429.60 163.14 9.51 2.63 515.68 3.16
    * Calculations performed considering isentropic compression and a housing loss of 10%. This is an estimated heat amount discarded in the discharge pipe and the condenser combined.
    Tables

    Condensing Temp. 35°C (Subcooling : 0 K, Return Temp.: 32 °C)

    Evaporating temperature Cooling capacity +/-5% Power consumption +/-5% Gas flow rate +/-5% Cooling Efficiency +/- 7% Heating capacity +/- 5% * Heating Efficiency +/- 7%
    °C W W kg/h W/W W W/W
    -15.00 198.48 99.10 3.96 2.00 245.93 2.48
    -10.00 247.83 106.91 4.96 2.32 299.29 2.80
    -5.00 307.85 114.36 6.19 2.69 362.71 3.17
    Charts

    Cooling capacity [W]

    Condensing temperature [°C]

    35

    45

    55

    Power consumption [W]

    Condensing temperature [°C]

    35

    45

    55

    Gas flow rate [kg/h]

    Condensing temperature [°C]

    35

    45

    55
Drawings